What is Fault Code 14 Intergas?

Published in Boiler Fault Codes 3 mins read

Fault code 14, often displayed as F014, on an Intergas boiler indicates a specific issue: the heat exchanger sensor is not mounted correctly and needs to be mounted properly. This error highlights a problem with how the sensor, vital for monitoring the heat exchanger's temperature, is positioned within the boiler system.

Understanding Intergas Fault Code F014

The heat exchanger sensor plays a critical role in the safe and efficient operation of an Intergas boiler. It continuously measures the temperature within the heat exchanger, allowing the boiler's control system to regulate heating and prevent overheating. When this sensor is dislodged or improperly installed, the boiler's control unit cannot receive accurate temperature readings, leading it to register fault code F014 and typically shut down as a safety measure.

Common Causes and Implications

Several factors can lead to an F014 error:

  • Improper Mounting: The sensor may have been incorrectly clipped or positioned during installation or previous maintenance.
  • Vibration: Over time, normal boiler vibrations can cause a loosely fitted sensor to become dislodged from its proper seating.
  • Maintenance Oversight: If the boiler recently underwent servicing, the sensor might not have been re-seated correctly by the technician.

When the heat exchanger sensor is not correctly mounted, the boiler's safety mechanisms are compromised, potentially leading to inefficient operation or preventing the boiler from firing up altogether.

Troubleshooting and Solutions for F014

Addressing an F014 fault primarily involves ensuring the heat exchanger sensor is securely in its correct position.

  1. Visual Inspection: Carefully inspect the area around the heat exchanger to locate the temperature sensor. Verify that it is properly seated and firmly attached in its designated mounting point.
  2. Re-mount the Sensor: If the sensor appears loose or dislodged, gently but firmly re-mount it, ensuring it clicks or locks into place securely.
  3. Professional Assistance: If the sensor appears to be mounted correctly but the fault persists, or if you are unsure about safely accessing or re-mounting internal boiler components, it is crucial to contact a qualified Gas Safe registered engineer. They can accurately diagnose the issue, which might include:
    • A faulty heat exchanger sensor itself.
    • Damage to the sensor's wiring.
    • Issues with the boiler's main control board.

Important Note: Always prioritize safety. Tampering with boiler components without proper qualifications can be dangerous and may void your warranty.

Intergas Boiler Fault Codes Overview

Understanding common Intergas fault codes can help in initial diagnosis. Here's a quick reference for F014 and related codes:

Fault Code Cause
F014 Heat exchanger sensor is not mounted correctly and needs to be mounted properly.
F003 Heat exchanger needs checking for contamination.
F009 Burner controller needs replacing.

Always consult a certified professional for any boiler repair or maintenance to ensure safety and proper functionality.