What is a TN-S System?

Published in Electrical Earthing System 4 mins read

A TN-S system is a specific type of electrical earthing arrangement designed for safety and efficient fault current management within an electrical supply network. It is characterized by a dedicated protective earthing conductor (PE) that runs separately from the neutral conductor throughout the system.

Understanding the TN-S Earthing Configuration

According to the provided reference, a TN-S system operates with a precise earthing methodology:

  • Single Earth Connection Point: A TN-S system has the neutral of the source of energy connected with earth at one point only, at or as near as is reasonably practicable to the source. This means the main earthing for the entire system occurs at the origin of the power supply, such as a transformer or generator.
  • Dedicated Protective Earth (PE) Conductor: From this single earthing point, a separate protective earth conductor (PE) is run throughout the installation. This conductor is distinct from the neutral (N) conductor.
  • Consumer Earthing Connection: The consumer's earthing terminal is typically connected to the metallic sheath or armour of the distributor's service cable into the premises. This ensures a robust and direct connection to the main earthing point of the supply.

Key Characteristics and Benefits of TN-S Systems

The design principles of a TN-S system offer several advantages, particularly concerning safety and electromagnetic compatibility:

  • Reduced Earth Currents in Consumer Premises: Because the neutral and earth are separated from the source, there are generally no significant earth return currents flowing through the consumer's protective earth conductors under normal operating conditions. This minimizes potential differences on exposed conductive parts.
  • Improved Safety: In the event of an insulation fault (e.g., a live conductor touching an earthed metal casing), a clear, low-impedance path back to the source is provided by the dedicated PE conductor. This ensures rapid operation of protective devices (like circuit breakers or fuses), quickly isolating the faulty circuit and reducing the risk of electric shock.
  • Electromagnetic Compatibility (EMC): The separation of neutral and earth helps in reducing electromagnetic interference. Fault currents and harmonic currents flow predominantly through the neutral conductor, not the protective earth, which is beneficial for sensitive electronic equipment.
  • Suitability for Large Installations: TN-S systems are often preferred for larger industrial and commercial installations due to their reliability and ability to manage significant fault currents safely.

How TN-S Compares to Other Earthing Systems

While the question focuses on TN-S, it's helpful to understand its place within the broader TN earthing family. The "TN" part signifies that the neutral is directly earthed at the source (Terra-Neutral) and the exposed conductive parts of the installation are connected to this earthed neutral via protective conductors (earthed by Network). The "S" in TN-S specifically denotes "Separate" neutral and earth conductors throughout the system.

Here's a brief overview of key features:

Feature Description
Neutral-Earth Connection Connected at one point only, at or very near the source of energy (e.g., utility transformer).
Protective Conductor A dedicated Protective Earth (PE) conductor runs separately from the Neutral (N) conductor from the source throughout the installation to the consumer's premises.
Fault Path Fault currents return to the source via the dedicated PE conductor.
Typical Application Often used in larger commercial, industrial, and sometimes older domestic installations where the distributor's cable provides a metallic sheath for earthing.
Advantages Low impedance fault loop, good safety from electric shock, reduced stray currents on earthing system, improved electromagnetic compatibility for sensitive equipment.

Practical Implications

In practice, for consumers, a TN-S connection means that the protective earth terminal in their premises (e.g., at the main distribution board) receives its earth connection directly from the metallic components of the incoming service cable provided by the electricity distributor. This provides a clear, reliable path for fault currents back to the source, ensuring the proper operation of protective devices and enhancing electrical safety.