How to reverse a single phase motor without a capacitor?

Published in Electrical Motors 4 mins read

To reverse the direction of a single-phase motor without a capacitor, you must change the relative direction of current flow in either the main (run) winding or the auxiliary (start) winding, but not both. This is typically achieved by altering the wiring connections of one of these windings.

Understanding Single-Phase Motor Reversal

Single-phase induction motors require a phase difference between their main (run) winding and auxiliary (start) winding to create a rotating magnetic field that initiates motor rotation. The direction of this rotation depends on the relative phase relationship between the magnetic fields produced by these two windings. To reverse the motor's spin, you need to reverse the magnetic polarity of one set of windings with respect to the other.

This principle applies to various types of single-phase motors, including split-phase motors, which often do not use an external capacitor for starting.

How to Reverse a Single-Phase Motor's Direction

The most common and effective method involves reconfiguring the connections of the auxiliary (start) winding.

Identifying Motor Windings

Before attempting any wiring changes, it's crucial to correctly identify the main and auxiliary windings.

  • Main (Run) Winding: Generally has lower resistance because it's made of thicker wire and designed for continuous operation.
  • Auxiliary (Start) Winding: Typically has higher resistance due to finer wire and more turns, designed for brief operation during start-up.

You can use a multimeter to measure the resistance across different wire pairs to identify them. Usually, motors designed for reversal will have accessible lead wires for both windings.

Reversing Steps

Follow these steps carefully to reverse the motor's direction:

  1. Disconnect Power: Always ensure the motor is completely disconnected from the power supply before touching any wiring. This is a critical safety step to prevent electric shock.
  2. Locate Winding Connections: Open the motor's terminal box or access panel to find the connections for the main and auxiliary windings. Motors designed for reversal often have four leads: two for the main winding and two for the auxiliary winding, or internal connections that allow for switching.
  3. Identify Current Connection Scheme: Note down the current wiring configuration. Typically, one end of the main winding and one end of the auxiliary winding are connected together to form a common point, and the other ends are connected to the power supply, often through a centrifugal switch for the auxiliary winding.
  4. Reverse Auxiliary Winding Polarity:
    • The simplest way to reverse the motor's direction is by switching the two leads of the auxiliary (start) winding where they connect to the rest of the circuit.
    • For example, if the auxiliary winding leads are labeled S1 and S2, and they are currently connected as S1 to Power and S2 to Common, you would swap them so S2 connects to Power and S1 connects to Common.
  5. Secure Connections: Once the leads are swapped, ensure all connections are tight and properly insulated.
  6. Test Motor: Briefly reconnect power and observe the motor's rotation. If done correctly, the motor should now spin in the opposite direction.
Current Configuration Leads Swapped Resulting Rotation
Auxiliary (S1, S2) connected to Main (M1, M2) in one way Auxiliary S1 & S2 are interchanged Reverse
Main (M1, M2) connected to Auxiliary (S1, S2) in one way Main M1 & M2 are interchanged Reverse

Practical Example (Conceptual)

Imagine a single-phase motor with four leads: Main (M1, M2) and Auxiliary (A1, A2).

  • Original Connection:
    • M1 and A1 connected together (Common).
    • M2 connected to Line 1 (L1).
    • A2 connected to Line 2 (L2) (often through a switch).
  • To Reverse:
    • Keep M1 and A1 as Common.
    • Keep M2 connected to L1.
    • Swap A1 and A2: Now, connect A2 to Common, and A1 to L2. This reverses the current direction through the auxiliary winding relative to the main winding.

Alternatively, you could swap the main winding leads while keeping the auxiliary winding connections as they were. This achieves the same outcome.

Safety Considerations

  • Always disconnect power before performing any wiring changes.
  • If unsure, consult a qualified electrician or the motor's wiring diagram.
  • Ensure all new connections are secure, insulated, and comply with local electrical codes.

This method is highly effective for single-phase induction motors (like split-phase motors) designed with separate main and auxiliary windings that allow for external manipulation of their connections. Shaded-pole motors, for instance, are generally not reversible this way due to their fixed design.